beautypg.com

Connection data, Electrical installation – Lenze E94AZHB0101 User Manual

Page 41

background image

Electrical installation

Connection data

4

EDKE94AZHB DE/EN/FR/ES/IT 1.0

41

l

H1_E_INST−−−−(DUMMYSEITEVOR)−−−

Connection data

Terminal X107

Labelling

Description

Connection of the motor holding brake

BD1
BD2

+ (Lenze: WH)
− (Lenze: BN)
E94AZHx0101: 24 V DC, max. 5.0 A
Observe correct polarity!

+ / −

Supply voltage for the motor holding brake (18 ... 30 V DC)
Observe correct polarity!

SSP94X6107

Terminal data

Conductor cross−section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb−in]

Flexible

0.5 ... 2.5

20 ... 12

Spring terminal

With wire end
ferrule

Stripping length or contact length: 8 mm

Terminal X121

Labelling

Description

DI

Connection for external control
in accordance with IEC 61131−2

GI

Reference potential

DO

Connection for external feedback
in accordance with IEC 61131−2

SSP940X121

Terminal data

Conductor cross−section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb−in]

Flexible

0.2 ... 2.5

24 ... 12

Spring terminal

With wire end
ferrule