beautypg.com

4 electrical installation, Important notes, Electrical installation – Lenze E94AZHB0101 User Manual

Page 38: 4electrical installation

background image

4

Electrical installation

Important notes

EDKE94AZHB DE/EN/FR/ES/IT 1.0

38

l

H1_E_INST−−−−(DUMMYSEITEVOR)−−−

4

Electrical installation

Important notes

,

During installation the notes given in the documentation for the standard
device must be observed!

(

Stop!

Requirements concerning the brake cable (connection BD1/BD2):

ƒ

The brake cables must be shielded if they are incorporated in the motor
cable.
– Operation with unshielded brake cables can destroy the motor brake

control.

– We recommend the use of Lenze system cables (motor cable with

separately shielded additional cores).

ƒ

When using a permanent magnet holding brake, ensure the correct
polarity of the brake cable.
– If the terminals are reversed, the brake does not release. Since the motor

runs against the closed brake, the brake can be destroyed.

ƒ

Connect the shield on both sides of PE.

Requirements concerning the supply voltage U

DC

(connection +/−):

ƒ

The motor brake control must always be supplied with a separate 24 V
supply.
– A common supply of the motor brake control and the control card of the

controller is not permissible since otherwise the double insulation
between both components would be reduced.

ƒ

Set U

DC

so that the operating voltage of the brake is within the admissible

range and the maximum supply voltage of the motor brake control will not
be exceeded.