beautypg.com

Mounting steps, Mechanical installation – Lenze E84AZESR RFI filter 3-29A User Manual

Page 55

background image

Mechanical installation

Mounting variant

5

EDK84AZESRx DE/EN/FR/ES/IT 2.0

55

l

H1_MechINS−FE−Filt_84_Var_Mont_Schritte

Mounting steps

Device size GG1 − GG3

Device size GG4 − GG5

E84AZESR008

E84AZESR021

Proceed as follows for installation:
1. Prepare M5 threaded holes on the mounting plate and equip them with screws and

washers.
– Two M5 screw and washer assemblies or M5 hexagon socket screws with washers

for the filter.

– Two M5 screw and washer assemblies or M5 hexagon socket screws with washers

for the standard device.

– Do not yet tighten the screws.

2. Remove the screw and washer assemblies from the filter to fix the standard device.
3. Mount the filter onto the prepared mounting plate.

– Only tighten the screws hand−tight.

4. Mount the standard device onto the prepared mounting plate.

– Observe the instructions in the documentation for the standard device.
– Only tighten the screws hand−tight.

5. If necessary, preassemble additional units.
6. Align all units.
7. Screw all units onto the mounting plate.

– Tightening torque: 3.4 Nm (30 lb−in)