English, Symbols used on lcd, Electrical specifications – Klein Tools CL3000 User Manual
Page 3

ENGLISH
•
Do not measure resistance
on a live circuit.
•
Ω
< 40MΩ
Resistance Features:
HOLD RANGE
4.
Frequency / Duty Cycle
Features:
HOLD
• Input Voltage should be between 1V-10V RMS for listed accuracy.
5. Resistance / Diode / Continuity
Display shows:
• Forward voltage drop if forward biased.
• “O.L.” if reverse biased.
Diode Features:
HOLD
• Display shows resistance.
• Buzzer sounds if less than 30
Ω
Continuity Features:
HOLD
6. Capacitance:
< 40µF
Features:
REL
HOLD
• ?
Safely discharge capacitor before measurement.
• Wait up to 60 seconds for reading.
PRESS
TO SELECT
Diode
Resistance
Continuity
AUTO
V
DC
PRESS
%
AUTO
V
DC
AUTO
V
DC
AUTO
V
DC
AUTO
V
DC
SYMBOLS USED ON LCD
~
AC Measurement
DC Measurement
-
Negative DC Value
REL
Relative Mode
Low Battery
H
Hold Active
AUTO
Auto Range Active
V
Voltage Measurement
%
Duty Cycle Mode
Frequency Mode
A
Current in Amps
Ω
Resistance in Ohms
Diode Test
Continuity Test
F
Capacitance in Farads
n
Nano 10
-9
µ
Micro 10
-6
m
Milli 10
-3
k
Kilo 10
3
M
Mega 10
6
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range
Resolution
Accuracy
4V
0.001V
± (0.7% + 2 digits)
40V
0.01V
400V
0.1V
1000V
1V
± (0.8% + 3 digits)
Overload Protection:
1000V DC / 750V AC RMS
Input Impedance:
10M
Ω
AC Voltage Measurement
Range
Resolution
Accuracy
4V
0.001V
± (0.8% + 5 digits)
40V
0.01V
400V
0.1V
750V
1V
± (1.0% + 10 digits)
Overload Protection:
1000V DC / 750V AC RMS
Frequency:
50 to 60Hz
Input Impedance:
10M
Ω
Response:
Averaging
AC Current Measurement
Range
Resolution
Accuracy
200A
0.1A
± (3.0% + 3 digits)
Overload Protection:
240A for 60 sec.
Frequency Response:
50 to 400Hz
Response:
Averaging