DESCRIPTION

The Klein Tools Distance Meter determines the length of a particular cable

by measuring the total capacitance of the cable attached to the unit and

comparing that to a preset or user defi ned capacitance per foot variable.

The Klein Tools Distance Meter has two alligator clip leads, an RJ-style

twisted pair plug and a coaxial F-connector jack for input into the meter.

The unit comes pre-programmed with nominal length constants for the

following cables:

RG-59 coaxial

RG-6 coaxial

RG-11 coaxial

Cat3 twisted pair

Cat5e twisted pair

Cat6 twisted pair

User mode allows the user to adjust the capacitance per foot constant,

based on the cable that needs to be tested.

The Klein Tools Distance Meter is powered by a standard 9V battery.

GENERAL SPECIFICATIONS

Dimensions: 4.9" x 2.7" x 1.4" (12.3 x 6.9 x 3.5 cm)
Weight: 7.5 oz. (213 g) with battery
Operating Temperature: 0°C / 32°F to 50°C / 122°F
Storage Temperature: -20°C / -4°F to 60°C / 140°F
Humidity: 10% to 90%, non-condensing
Fault Volt Tolerance: Reports voltage present up to 20 volts AC or DC
Battery Life: 9V Alkaline Battery, typical

Active: 425 hours
Standby: 4 years

Length Measurement

Method: Capacitance
Resolution: 1 ft (0.3 meter)
Length Constant Range: 10 to 40pF/ft (33 to 132pF/meter)
Accuracy (with known length constant):

+/-5% plus +/-1ft (+/-5% plus +/-0.3 m)

Maximum Range: 1500 ft / 450m on most cables

BATTERY REPLACEMENT

• To replace the battery, lightly pry off the bottom rubber cover,

and disconnect the leads.

• The device will turn itself off after fi ve minutes of non-use.
• The Battery Icon will fl ash if voltage drops below 6V, and turn

unit off after voltage drops below 5V.

VDV Distance Meter