beautypg.com

JUMO 902006 RTD Temperature Probe for Devices and Plants Tested According to DIN EN 14597 Data Sheet User Manual

Page 7

background image

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866

1-800-554-5866

Fax:

315-437-5860

E-mail:

[email protected]

Internet: www.jumousa.com

2013-07-30/00311472

Data Sheet 902006

Page 7/12

Push-in RTD temperature probe
with displaceable stop flange and terminal head
according to DIN 43729, form B, M24 × 1.5

Insertion
length
EL in mm

Nominal length
NL in mm

Temperature
range in °C

Type
up to February
28, 2013
1× Pt100

Type
up to February
28, 2013
2× Pt100

Type
as of March 01, 2013

Order code

Stainless steel protection tube X 6 CrNiMoTi 17 12 2, material-no. 1.4571

50 to 460

500

-170 to +700

x

-

902006/65-228-1003-1-15-500-668/000

50 to 670

710

-170 to +700

x

-

902006/65-228-1003-1-15-710-668/000

50 to 960

1000

-170 to +700

x

-

902006/65-228-1003-1-15-1000-668/000

50 to 460

500

-170 to +700

-

90.271-F01

902006/65-228-2003-1-15-500-668/000

50 to 670

710

-170 to +700

-

90.272-F01

902006/65-228-2003-1-15-710-668/000

50 to 960

1000

-170 to +700

-

90.273-F01

902006/65-228-2003-1-15-1000-668/000

Important information:

Please observe the internal lead wire resistance with respect to the operating temperature;

see the final page for the resistance values.

Operating medium: air

● Available from stock. Pos. 5

Versions only for connecting a
JUMO safetyM STB/STW Ex type 701155

Insertion
length
EL in mm

Nominal length
NL in mm

Temperature
range in °C

1× Pt100

2× Pt100

Type
Order code

Stainless steel protection tube X 6 CrNiMoTi 17 12 2, material-no. 1.4571

50 to 460

500

-170 to +700

x

-

902006/65-228-1003-1-15-500-668/922

50 to 670

710

-170 to +700

x

-

902006/65-228-1003-1-15-710-668/922

50 to 960

1000

-170 to +700

x

-

902006/65-228-1003-1-15-1000-668/922

50 to 460

500

-170 to +700

-

x

902006/65-228-2003-1-15-500-668/922

50 to 670

710

-170 to +700

-

x

902006/65-228-2003-1-15-710-668/922

50 to 960

1000

-170 to +700

-

x

902006/65-228-2003-1-15-1000-668/922

Important information:

Please observe the internal lead wire resistance with respect to the operating temperature;

see the final page for the resistance values.

Operating medium: air

Pos. 5