beautypg.com

Connection diagram, Wiring diagrams, Approval/approval marks – JUMO 60.4514 Hot air thermostats, WTHc Data Sheet User Manual

Page 3

background image

2013-06-20/00332482

Data Sheet 604514

Page 3/5

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866

1-800-554-5866

Fax:

315-437-5860

E-mail:

[email protected]

Internet: www.jumousa.com

Approval/approval marks

Connection diagram

The connection diagram in the data sheet provides preliminary information about the connection possibilities. For the electrical connection only
use the operating manual. The knowledge and the correct technical execution of the safety information/instructions contained in these docu-
ments are mandatory for installation, electrical connection, and startup as well as for safety during operation.

Wiring diagrams

Case

Standard

Case lid: polycarbonate
Case bottom part: sheet steel, painted

Color: pebble gray RAL 7032

Extra code "SW"

Case lid: polycarbonate
Case bottom part: aluminum die casting, painted

Color: pebble gray RAL 7032
Colour: anthracite gray RAL 7015

Setpoint value setting

Safety temperature limiter STB:
permanently factory-set

Ventilator controller TR and burner monitor TW:
The switching point can be adjusted by using a
screwdriver once the case lid has been removed

Standard

For extra code /SW

Protection type

EN 60 529-IP 40

EN 60 529-IP 54

Cable inlet

2 plug-type sockets

EN 60 529-IP 54

Mounting of switching head

With 2 screws through the case bottom part

With 2 screws on the support tube flange, then with
one screw on the hexagonal part of the support tube

Weight

Approx. 0.7 kg

Approval marks

Inspection authority

Certificates /
inspection number

Inspection basics

Valid for

DIN

DIN CERTCO / TÜV Süd

TR/TW/STB1064

DIN EN 14597

WTHc hot air thermostats

DIN

DIN CERTCO / TÜV Süd

TR/TW/STW1205

DIN EN 14597

Note

Physical and toxic features of the expansion means, which could emerge in the event of a measuring system break.

Control range
with scale limit value

Hazardous
reactions

Fire and explosion hazard

Hazardous to
waters

Information about toxicology

Ignition
temperature

Explosion
limit

Irritant

Dangerous to
health

Toxic

≤ +200 °C

No

+355 °C

0.6 - 8 V%

Yes

Yes

a

a

At present, no statement concerning health hazards in the event of short-term exposure and low concentration (e.g. measuring system rupture) has been made by
the health authority

No

( 1 ) TR (ventilator)
( 2 ) TW (burner)
( 3 ) STB (burner)

WTHc-2280, WTHc-2280 to /402

WTHc-2240 to /574, WTHc-2240 to /402, 547

1

2

3

4

5

6

1

4

2

( 1 )

1

4

2

2

1

( 2 )

( 3 )

1

2

3

4

5

6

1

4

2

1

4

2

II

I

4

2

4

7

1

( 1 )

( 2 )

( 3 )