Connection diagram, Wiring diagrams, Approval/approval marks – JUMO 60.4514 Hot air thermostats, WTHc Data Sheet User Manual
Page 3
2013-06-20/00332482
Data Sheet 604514
Page 3/5
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone:
+49 661 6003-0
Fax:
+49 661 6003-607
E-mail:
Internet:
www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:
+44 1279 635262
E-mail:
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866
1-800-554-5866
Fax:
315-437-5860
E-mail:
Internet: www.jumousa.com
Approval/approval marks
Connection diagram
The connection diagram in the data sheet provides preliminary information about the connection possibilities. For the electrical connection only
use the operating manual. The knowledge and the correct technical execution of the safety information/instructions contained in these docu-
ments are mandatory for installation, electrical connection, and startup as well as for safety during operation.
Wiring diagrams
Case
Standard
Case lid: polycarbonate
Case bottom part: sheet steel, painted
Color: pebble gray RAL 7032
Extra code "SW"
Case lid: polycarbonate
Case bottom part: aluminum die casting, painted
Color: pebble gray RAL 7032
Colour: anthracite gray RAL 7015
Setpoint value setting
Safety temperature limiter STB:
permanently factory-set
Ventilator controller TR and burner monitor TW:
The switching point can be adjusted by using a
screwdriver once the case lid has been removed
Standard
For extra code /SW
Protection type
EN 60 529-IP 40
EN 60 529-IP 54
Cable inlet
2 plug-type sockets
EN 60 529-IP 54
Mounting of switching head
With 2 screws through the case bottom part
With 2 screws on the support tube flange, then with
one screw on the hexagonal part of the support tube
Weight
Approx. 0.7 kg
Approval marks
Inspection authority
Certificates /
inspection number
Inspection basics
Valid for
DIN
DIN CERTCO / TÜV Süd
TR/TW/STB1064
DIN EN 14597
WTHc hot air thermostats
DIN
DIN CERTCO / TÜV Süd
TR/TW/STW1205
DIN EN 14597
Note
Physical and toxic features of the expansion means, which could emerge in the event of a measuring system break.
Control range
with scale limit value
Hazardous
reactions
Fire and explosion hazard
Hazardous to
waters
Information about toxicology
Ignition
temperature
Explosion
limit
Irritant
Dangerous to
health
Toxic
≤ +200 °C
No
+355 °C
0.6 - 8 V%
Yes
Yes
a
a
At present, no statement concerning health hazards in the event of short-term exposure and low concentration (e.g. measuring system rupture) has been made by
the health authority
No
( 1 ) TR (ventilator)
( 2 ) TW (burner)
( 3 ) STB (burner)
WTHc-2280, WTHc-2280 to /402
WTHc-2240 to /574, WTHc-2240 to /402, 547
1
2
3
4
5
6
1
4
2
( 1 )
1
4
2
2
1
( 2 )
( 3 )
1
2
3
4
5
6
1
4
2
1
4
2
II
I
4
2
4
7
1
( 1 )
( 2 )
( 3 )