beautypg.com

Approvals/approval marks – JUMO 605055 exTHERM-AT Data Sheet User Manual

Page 3

background image

2014-07-15/00576368

Data Sheet 605055

Page 3/9

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866

1-800-554-5866

Fax:

315-437-5860

E-mail:

[email protected]

Internet: www.jumousa.com

Approvals/approval marks

Electrical data

Max. switching capacity

Selectable on the N/C contact (contact deck 1-2):
AC 400 V +10 %, 16 A

AC 230 V +10 %, 16 (2.5) A, cos

ϕ = 1 (0.6)*

AC 230 V +10 %, 25 (4) A, cos

ϕ = 1 (0.6)

DC 230 V +10 %, 0.25 A
Selectable on the N/O contact (contact deck 1-4):
TW, STW

STB

AC 400 V +10 %, 6.3 A

AC 230 V +10 %, 6.3 (2.5) A, cos

ϕ = 1 (0.6)*

AC 230 V +10 %, 2 (0.4) A, cos

ϕ = 1 (0.6)

DC 230 V +10 %, 0.25 A

AC 400 V +10 %, 2 A

AC 230 V +10 %, 2 (0.4) A, cos

ϕ = 1 (0.6)*

AC 230 V +10 %, 2 (0.4) A, cos

ϕ = 1 (0.6)

AC 230 V +10 %, 0.25 A

Snap-action switch, gold-plated AC / DC = 24 V, 0.1 mA

Min. switching capacity

To ensure the greatest possible switching reliability we recommend a minimum load of:

AC / DC = 24 V, 100 mA for silver contacts

AC / DC = 10 V, 5 mA for gold-plated contacts

* standard

Capillary and temperature probe

Type

Capillary

1.5 mm

Temperature probe

JUMO exTHERM-AT

Stainless steel (CrNi) 1.4571

Stainless steel (CrNi) 1.4571, welded

Capillary length

Max. 5000 mm

Capillary bending radius

≥ 5 mm

Control ranges and probe table

Control range

Max.

capillary length

Probe length "L"

For "d" = 4 mm

For "d" = 6 mm

TW

STW, STB

TW

STW, STB

Hysteresis

In °C

In mm

Approx. 2.5 %

Approx. 7 %

Approx. 2.5 %

Approx. 7 %

-20 to +50

5000

- -

- -

138

81

0 to +120

203

113

90

58

0 to +200

154

87

72

48

+130 to +190

- -

- -

115

70

+50 to +300

135

78

65

- -

+20 to +500

- -

- -

278

- -

+140 to +500

- -

- -

- -

126

Switching point tolerance in the middle section of the scale

Control range

in °C

TW

in K

STW upward adjustment

in K

STW downward adjustment

in K

STB

in K

-20 to +40

+2/-2

- -

- -

- -

-20 to +50

+3/-3

+0/-5

+5/-0

+0/-5

0 to +100

+5/-5

+0/-10

+10/-0

+0/-10

0 to +120

+5/-5

+0/-10

+10/-0

+0/-10

+130 to +190

+8/-8

+0/-16

+16/-0

+0/-16

0 to +200

+8/-8

+0/-16

+16/-0

+0/-16

+50 to +300

+12/-12

+0/-24

+24/-0

+0/-24

+20 to +500

+22/-22

- -

- -

- -

+140 to +500

+22/-22

+0/-44

+44/-0

+0/-44

Temperature monitors (TW) and safety temperature monitors (STW) are adjusted ascendingly in the middle section of the scale as standard
procedure. Safety temperature limiters (STB) are adjusted in the upper section of the scale. Special adjustments are possible upon request.

JUMO exTHERM-AT

Switching function

Certificates/test confirmations

Tests

TW

EPS 11 ATEX 1 354

ATEX

STW

IECEx EPS 13.0046

IECEx

TZ 372

STB

POCC DE.ME92.B02680

GOST