Data Sheet 602021

2014-01-20/00073206

Page 5/14

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866

1-800-554-5866

Fax:

315-437-5860

E-mail:

[email protected]

Internet: www.jumousa.com

Operating data

Casing

Process connection*

* See data sheet 606710 for additional process connections and thermowells

Switching point
accuracy
in % of control range/
limit value range

Switching function

Switching differential

In the upper third of the scale

or limit value

Liquid-filled

Gas-filled

TR

1 %, 2.5 %

5 %
7 %

-

3 %, 5 %

6 %, 10 %

±1.5 %

±3 %
±4 %

TW

1 %, 2.5 %

5 %
7 %

-

3 %, 5 %

6 %, 10 %

±1.5 %

±3 %
±4 %

TB

-

-

+0 %

-5 %

STB, STW (STB)

See table for control ranges and probes on page 3

Mid ambient
temperature influence

Deviation of the ambient temperature at the switching head and/or capillary

from the 22 °C calibration ambient temperature produces a switching point offset.

Higher ambient temperatures = lower switching point

Lower ambient temperature = higher switching point

For temperatures with scale limit value/limit value

< 200 °C

≥ 200 °C ≤ 350 °C

≥ 400 °C ≤ 500 °C

TR, TW, TB

STW, STB

TR, TW, TB

STW, STB

TR, TW, TB, STW, STB

Switching differential in %

1/2.5

5

7

7/-

1/2.5

5

7/-

3/5

6

10

Ambient temperature influence on the switching head in %/°C

0.15

0.26

0.34

0.43

0.12

0.21

0.35

0.12

0.17

0.24

Ambient temperature influence on the capillary in %/m

0.05 × °C × m

0.09 × °C × m

0.04 × °C × m

0.07 × °C × m

0.05 × °C × m

Temperature
compensation* (TK)

* For detailed information see diagram on page 9

Temperatures

Allowable storage temperature: -50 to +50 °C

Allowable ambient temperature for use: Max. 80 °C

Nominal position (NL)

Any

Casing:
galvanized sheet steel

Standard mounting With 2 M3 screws, spaced 22 mm

Extra code 704 With 2 M4 screws, spaced 28 mm

Extra code 705 With 2 M3 screws, spaced 33 mm

Extra code 710 Central mounting M10 × 1 with acorn nut (only for TB and STB)

Setpoint value setting

TR:

Switching point adjustable from the outside using

the rotary knob

TW, TB, STB, STW (STB):

Switching point adjustable with a screwdriver

Types EM-3, EM-4, EM-33, EM-44, EM-444, EM-3333, EM-30, EM-40

Permanently set at the factory to customer requirements

Setpoint adjuster

See data sheet 606715

Scale range

Standard: 250°

Մ (for STB and STW (STB) see table for control ranges and probes on page 3)

Protection type

EN 60529-IP00

Weight

Approx. 0.3 kg

EM series
with capillary

Plain cylindrical probe "10" (standard)

Screw-in thermowell "20" (upon request)

Screw-in sleeve with screw-in spigot G 1/2 form A as per DIN 3852/2

and clamping piece with fixing screw for securing the probe

Material

Thermowell

Up to 150 °C CuZn as standard
Above 150 °C CrNi

Insertion length S

Standard lengths: 100, 120, 150, 200, or 300 mm (different lengths upon request)

Immersion tube Ø

D = 8 mm, D = 10 mm