Johnson Systems EDI-120 Control Retrofit User Manual
Page 27

27
29. S-ALARM
Select the level and control channels triggered by the security alarm input.
When a contact is sensed on the security alarm input, the selected control channels
will cycle on and off at a 1 hertz rate (one cycle per second). The level of the on cycle
can be set from 0% to 100%. The security alarm input takes precedence over the
DMX and analog inputs. The system will stay in security alarm mode until the contact
is removed. The factory default is all control channels at full-on.
Press EXECUTE to enter the menu and configure the security alarm input.
LFLC001*
Displays the output level (L) of 100% (FL) and control channel (001*).
L00C001*
Press MENU ( ) to change the output level from 00% to 100% (FL).
LFLC001*
Press MENU ( ) at the same time to toggle the level back to 100% (FL).
LFLC001*
Press EXECUTE to toggle from level (L) to channel (C) selection.
LFLC001*
The cursor (_) position indicates level (L) or channel (C) selection.
LFLC120*
Press MENU ( ) to select the desired control channel from 001 to 120.
LFLC120
Press EXECUTE to toggle the patch flag (*) for each desired control channel.
LFLC120*
The patch flag (*) indicates the channel will be triggered by the security alarm.
LFLC120*
Press ESCAPE to toggle the cursor (_) back to level (L) selection.
Press ESCAPE to exit the menu and save the desired settings.
Press RESET to exit the menu without saving.
The menu will automatically timeout after 5 minutes of inactivity and save.
30. F-ALARM
Select the level and control channels triggered by the fire alarm input.
When a contact is sensed on the fire alarm input, the selected control channels are
triggered on to the selected output level from 0% to 100%. The fire alarm input is
merged with the DMX and analog inputs with highest takes precedence (HTP). The
system will stay in fire alarm mode until the contact is removed. The factory default is
all control channels at full-on.
Press EXECUTE to enter the menu and configure the fire alarm input.
LFLC001*
Displays the output level (L) of 100% (FL) and control channel (001*).
L00C001*
Press MENU ( ) to change the output level from 00% to 100% (FL).
LFLC001*
Press MENU ( ) at the same time to toggle the level back to 100% (FL).
LFLC001*
Press EXECUTE to toggle from level (L) to channel (C) selection.
LFLC001*
The cursor (_) position indicates level (L) or channel (C) selection.
LFLC120*
Press MENU ( ) to select the desired control channel from 001 to 120.
LFLC120
Press EXECUTE to toggle the patch flag (*) for each desired control channel.
LFLC120*
The patch flag (*) indicates the channel will be triggered by the fire alarm.
LFLC120*
Press ESCAPE to toggle the cursor (_) back to level (L) selection.
Press ESCAPE to exit the menu and save the desired settings.
Press RESET to exit the menu without saving.
The menu will automatically timeout after 5 minutes of inactivity and save.
31. Ø-PATCH
Set the zero-cross phase reference for each dimmer control output circuit.
EDI Mark VII dimmer racks are typically powered by 3-phase, with the dimmer
phase reference configured for AABBCC (dimmers 1 and 2 are powered by phase A,
dimmers 3 and 4 are powered by phase B, dimmers 5 and 6 are powered by phase
C, etc). The defaults (DEFAULTS) menu is normally used to configure the phase
patch for standard applications. This menu provides custom phase patching for non-
standard applications.
If a dimmer control output is patched to the incorrect phase reference, the dimmer will
not dim correctly and will go to full output at around 1% DMX input.
Press EXECUTE to enter the menu and configure the dimmer phase patch.
C 001 ØA
Displays the dimmer channel (C) output (001) and the patched phase (ØA).
C 120 ØC
Press MENU ( ) to change the dimmer channel to patch from 001 to 120.
C 120 ØA
Press EXECUTE to toggle the patch to Phase A (ШA).