beautypg.com

Power supply connection details, Dimmer output – Johnson Systems JS-ICON 624 ARCH Dimmer Rack User Manual

Page 8

background image

www.johnsonsystems.com

8

www.johnsonsystems.com

9

Neutral Power

Input

To Phase

Reference PCB

#18 AWG Wire

Neutral Output To Load 1 - 6

Earth

Ground

Output

To Load

1 - 6

Load (Hot) Output 1 - 6

#12 AWG Factory Wiring

Power Supply Connection Details

Neutral Power Distribution Block

Neutral Input: Use 350 kcmil to #6 AWG copper wire only, rated for 90°C

minimum.

Torque to 31 NM (275 LB-IN).

Load Output: Use #4 AWG to #14 AWG copper wire only, rated for 90°C

minimum.

Torque #4 AWG to #6 AWG wire to 3.95 NM (35 LB-IN).

Torque #8 AWG wire to 2.82 NM (25 LB-IN).

Torque #10 AWG to #14 AWG wire to 2.26 NM (20 LB-IN).

Load Grounding Terminal

• Use #4 AWG to #14 AWG copper wire only, rated for 90°C minimum.

• Torque #4 AWG to #6 AWG wire to 3.95 NM (35 LB-IN).

• Torque #8 AWG wire to 2.82 NM (25 LB-IN).

• Torque #10 AWG to #14 AWG wire to 2.26 NM (20 LB-IN).

• Torque two (2) #10 AWG to #14 AWG wires to 2.82 NM (25 LB-IN).

Dimmer Output

Six (6) 2400 Watt dimmers (maximum rating 14,400 Watts at 120 VAC).
JS-ICON

624 ARCH dimmers are designed for high performance dimming

of standard incandescent, quartz, and dimmable (SCR/Leading-Edge)

electronic low-voltage fixtures. Remove the contractor wiring access panel to

locate the contractor termination section, where the required load terminals

are located. Knockouts on the top and bottom of the chassis are provided for

wire/conduit entry to the load terminals.

Load Output Connection Details
Load connections are terminated via six (6) tension clamp terminals.

• Use #8 AWG to #20 AWG copper wire only, rated for 90°C minimum.

• Strip 0.39” (10mm) of insulation from the end of each load conductor.

• Pry the tension clamp open by inserting a small flathead screwdriver

into the square slot.

• Insert the load conductor into the tension clamp, and remove the

flathead screwdriver.