beautypg.com

Troubleshooting – Intelix S-V1AR User Manual

Page 3

background image



Troubleshooting

Symptom

Probable Causes

Possible Solutions

Image not stable

Defective link or
equipment

Verify source and destination equipment and
cabling

Unusual colors

Reversed polarity

Verify the pinout on both the send and
receive baluns match. Try swapping pairs.

Smearing or weak
video contrast

Exceeded cable
distance

Verify cable grade and total cabling distance

Horizontal bars
moving upward in
background

Ground loop
problem

Verify the source and destination equipment
are at the same ground potential. Ground the
source and destination equipment.

Shaking image

Ground loop
problem

Verify the source and destination equipment
are at the same ground potential. Ground the
source and destination equipment.

Variance in hue

EMI interference

Identify possible radiating frequency sources
and isolate them from the cabling. Use
shielded twisted pair cabling.

Background
pattern

EMI interference

Identify possible radiating frequency sources
and isolate them from the cabling. Use
shielded twisted pair cabling.