3.3 Status and Error
The SPI communication string for reading the status value consists of total 4 bytes as follows:
0x48 – 0x00 – 0x00 – 0x00, only the first byte is relevant, the other three must be sent but the content
of them doesn’t matter.
Read Status Op-Code:
Byte_3
Byte_2
Byte_1
Byte_0
0 1 0 0 1 0 0 0
don’t care
Status result:
Byte_3
Byte_2
Byte_1
Byte_0
don’t’ care
24-Bit Status value (Bit 23..0)
Bit
Description
23 SPI communication took place during measurement
13 Pressure error
8
port 3 error
7
port 2 error
6
port 1 error
5
port 0 error
3
Temperature error
All other bits not mentioned here must be ignored.
3.4 Power-up reset
After powering up the device, it must be reset by sending the reset command to the device. The reset
command consists of the single byte 0x88h. It is highly recommended to send the reset command
(0x88h) to the sensor after every power up.