INCRA TS-LS Metric Extended User Manual
Incra ts-ls, Metric extended capacity instructions
INCRA TS-LS
Metric Extended Capacity Instructions
Installing your new fence system with the TS-
LS Owner’s Manual will provide 810mm of right-side
ripping capacity. These instructions will increase that capacity to 1320mm on most saws.
Note:
When installing the longer
92” rails, the only departure from TS-LS Owner’s Manual is that
the right-
hand end of the rails should be 1650mm from the blade instead of 45” (page 5, step 5).
Complete the entire installation
and set the LS positioner’s steel primary scale before using these
instructions to set up the system for extra capacity.
1.
Slide the “floating EL” stops from Hardware Pack B-05 into the T-slots on the bottom of the
main rails and tighten them against the edges of the base clamps that are nearest the blade
(see page 12 of the TS-
LS Owner’s Manual). These stops will be used to position the base
on the rails for cuts made from 0
– 810mm wide.
2.
If you haven’t already done so, install the rail support legs 200 – 400mm from the ends of the
rails. Set the l
evelers so the ends of the rails don’t appear to rise or sag when sighting down
the rail’s length.
3. Set the fence 510mm from the blade using the steel scale and fully lock the red lever on the
LS positioner. Leave the ends of the fence unlocked.
4. Clamp blocks of scrap wood onto the infeed and outfeed main rails so they rest gently against
the face of the fence. (Fig. 1)
Fig. 1- Scrap wood blocks clamped to rails
5. On the dual-pilot rectangular nuts that hold the base clamping knobs, loosen the small set
screws with an Allen wrench so the knobs and base assembly can slide freely up and down
the rails. A drop of Loc-tite on the threads of the set screws will hold them in place in the nuts
if you choose to leave them loose.