16 electrical connections supply voltage plug x1, Signals plug x2, Relay plugs x3 / x4 – HYDAC HDA 5500-3-2-DC-000 User Manual
Page 22

HDA 5500 User Manual
- 22 -
16 Electrical connections
Supply voltage plug X1
X1
UNIT
PIN
DESCRIPTION
Models
HDA 5500 – X – X – AC – 000 ~ / ~
Supply voltage inputs 85 VAC to 265 VAC 50 / 60 Hz
1 , 2 and 3
HDA 5500 – X – X – DC – 000 + / -
Supply voltage inputs 24 VDC
1 , 2 and 3
Signals plug X2
X2
UNIT
1
2
3
4
5
6
7
8
9
10
11
Models
HDA 5500 – 0 – X – XX – 000
RXD
TXD
DGND
Analogue
output
AGND
+12 V
Sensor 1
input
1 , 2 and 3
HDA 5500 – 1 – X – XX – 000
RXD
TXD
DGND
Analogue
output
AGND
+12 V
Sensor 1
input
Sensor 2
input
Sensor 3
input
AGND
1 , 2 and 3
HDA 5500 – 2 – X – XX – 000
RXD
TXD
DGND
Analogue
output
AGND
+12 V
Sensor 1
input
Freq
Start
Stop
Clear
1 , 2 and 3
HDA 5500 – 3 – X – XX – 000
RXD
TXD
DGND
Analogue
output
AGND
+12 V
Sensor 1
input
Pt100
Pt100
Pt100
Pt100
1 , 2 and 3
Relay plugs X3 / X4
X3
X4
UNIT
1
2
3
4
5
6
1
2
3
4
5
6
Models
HDA 5500 – X – 0 – XX – 000
1
HDA 5500 – X – 1 – XX – 000
R1
N/C
R1
Common
supply
R1
N/O
R2
N/C
R2
Common
supply
R2
N/O
2
HDA 5500 – X – 2 – XX – 000
R1
N/C
R1
Common
supply
R1
N/O
R2
N/C
R2
Common
supply
R2
N/O
R3
N/C
R3
Common
supply
R3
N/O
R4
N/C
R4
Common
supply
R4
N/O
3
HDA 5500-X-2-XC-000
HDA 5500-X-0-XC-000
HDA 5500-X-1-XC-000