beautypg.com

3 safety relevant data, Identification data value standard, As-i safety output relay with four standard inputs – EUCHNER AS-i Safety Output Relay with four standard inputs User Manual

Page 13

background image

AS-i Safety Output Relay with four standard inputs

Product Description

Subject to reasonable modifications due to technical advances

Id.-No.: 103573

Issue date - 28.5.2009

EUCHNER GmbH + Co. KG

13

Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0 • Fax. +49/711/753316

4.3

Safety relevant data

1.) The PFD and PFH D values stated here are related to the maximum operating time of 12 month and a
maximum usage time of 20 years according to EN ISO 13849-1.
The relay’s maximum switch time (including the occurrence of errors) is 50 ms starting at the time the code
sequence is present until the switch-off of the relay. Additionally, the response time of the monitor and the
inputs must be included.

Identification data

Value

Standard

Safety category

4

EN 954-1

Safety category

4

EN 13849-1:2006/PLe
Cat 4

Performance level (PL)

e

Safety integrated level (SIL)

3

IEC 61508

Usage time (TM) in years

20

EN 13849-1:2006/PLe
Cat 4

Maximum operating time in month

12

IEC 61508

PFD

1

2

*

10

-5

IEC 61508 EN 62061

PFH

D

1

(Probability of a dangerous failure per hour)

3,3

*

10

-9

IEC 61508 EN 62061

Max. system reaction time in milliseconds

50

IEC 61508