background image

Operating Instructions Read Heads/Actuators for Evaluation Units CMS

Subject to technical modifications; no r

esponsibility is accepted for the accuracy of this information.

© EUCHNER GmbH + Co. KG

085673-11-01/13 (translation of the original operating instructions)

Figure 2: Dimension drawings for read heads CMS-R-A.. / CMS-R-B..

Dimension drawings for actuators CMS-M-A. / CMS-M-B.

The dimensions of the actuators are the

same as those of the read heads, although

the former have no connection cable.

CMS-R-A..

CMS-M-A.

2,5

2,5

S

ao

78

±0,1

∅ 5,5

9,

5

25

12

6

6

67,5

87,5

2,

5

13

42

ca

.

5,

8

Actuator

Active face

Center offset m at s = 3 mm

Yellow LED indicator

Only on version CMS-R-AXR

CMS-R-B..

CMS-M-B.

2,5

2,5

S

ao

19

,2

26

,2

22

7

36

13

5

8,5

4,5

42

ca

.

5,

8

0,34 mm²

Actuator

Active face

Center offset m at s = 3 mm

Technical data

Parameter

Value

Read heads
Housing material

Fiber glass reinforced PPS

Ambient temperature

-20 ... +60 °C

Degree of protection

according to EN 60529

IP 67

Installation position

Any, alignment with actuator

should be kept in mind (markings)

Connection

Molded cable with crimped

ferrules

Switching voltage

24 V DC

Switching current I

e

max.

0.5 A

Contact status indication (only CMS-R-AXR...)
Switching voltage

24 V DC

Switching current I

e

max.

0.015 A

Method of operation

Magnetic, reed contact

Mechanical life

100 x 10

6

operating cycles

Vibration resistance

10 ... 55 Hz, amplitude 1 mm

Shock resistance

30 g/ 11 ms

EMC compliance

According to EN 60947-5-3

Center offset m from actuator ± 2.5 mm at a distance of s =

3 mm

Switch-on distance s

ao

See

combination options table

Switch-off distance s

ar

Switching contacts
Actuator
Housing material

Fiber glass reinforced PPS

Ambient temperature

-20 ... +60 °C

Degree of protection

according to EN 60529

IP 67

Installation position

Any, alignment with read head

should be kept in mind (markings)

Method of operation

Magnetic

Vibration resistance

10 ... 55 Hz, amplitude 1 mm

Shock resistance

30 g/ 11 ms

Center offset m from read

head

± 2.5 mm at a distance of s =

3 mm

Switch-on distance s

ao

See combination options table

Switch-off distance s

ar

Figure 1: Alignment of read head and actuator

X

Y

Z

Alignment

marking

Approach

direction

X

Y

Z

Approach

direction

Alignment

marking

X

Y

Z

Approach

direction

Alignment

marking

Design CMS-.-A...

Design CMS-.-B...

Design CMS-.-C... / CMS-.-E...

Service and inspection

Remove iron swarf from the read head and actuator

at regular intervals.

Only use solvent-free detergents for cleaning the

actuators and read heads!

Regular inspection of the following is necessary

to ensure trouble-free long-term operation:

f

correct switching function

f

secure mounting of components

f

loose connections.

In the event of damage or wear and tear, the

damaged system component must be replaced.

Exclusion of liability under the following

conditions:

f

incorrect use

f

non-compliance with safety regulations

f

installation and electrical connection not per-

formed by authorized personnel

f

failure to perform functional checks.

0,34 mm²

(6 x 0,25 mm²

with CMS-R-AXR)