Functional check

After installation and any fault, the safety function must be fully checked. Proceed 

as follows:

Warning!

Danger of fatal injury as a result of faults in installation and functional check.

 Ì

Before carrying out the functional check, make sure that there are no per-
sons in the danger area.

 Ì

Observe the valid accident prevention regulations.

1.  Switch on operating voltage.

 Ì

The STATE LED then flashes at regular intervals.

2.  Close all safety guards.

 Ì

The machine must not start automatically.

 Ì

The green STATE LED illuminates continuously.

3.  Enable operation in the control system.
4.  Open the safety guard.

 Ì

The machine must switch off and it must not be possible to start it as long as 

the safety guard is open.

 Ì

The green LED STATE flashes at regular intervals.

Repeat steps 2-4 for each safety guard.