Operating instructions safety system ces-ap-c.2-ah, Plug connector with latching connection, 6-pin, Connection cable with m12 plug connector, 5-pin – EUCHNER CES-AP-CL2-AH (Unicode) User Manual
Page 12
Operating Instructions Safety System CES-AP-C.2-AH
12
Connector assignment and wire color for safety
switch CES-AP-C.2-AH
plug connector with latching connection, 6-pin
Fig. 1: Connector assignment, plug connector with latching connection
Pin Designation
Description
Wire color
1
UB
Power supply, DC 24 V
BN
2
OA
Safety output, channel 1
WH
3
0V
Ground, DC 0 V
BU
4
OB
Safety output, channel 2
BK
5
OUT
Door monitoring output
GY
6
-
Not used
PK
Connection cable with M12 plug connector, 5-pin
Fig. 2: Connector assignment, connection cable with M12 plug connector
Pin
Designation
Description
Wire color
5-pin
5-pin
Pin 5
not
used
1
1
UB
Power supply, DC 24 V
BN
2
2
OA
Safety output, channel 1
WH
3
3
0V
Ground, DC 0 V
BU
4
4
OB
Safety output, channel 2
BK
5
-
OUT
Door monitoring output
GY
View on the connection side of the safety switch
S1.1
S1.3
S1.6
S1.2
S1.4
S1.5
+UB
0V
NC
OA
OB
OUT
5
1
4
6
2
3
Coding lug
View on the connection side of the safety switch
S1.1
S1.3
S1.2
S1.4
S1.5
+UB
0V
OA
OB
n.c.
4
1
5
2
3
S1.1
S1.3
S1.2
S1.4
S1.5
+UB
0V
OA
OB
OUT
Coding lug
5-pin
5-pin,
pin 5 not used