TROUBLESHOOTING (cont.)
Problem

Brew cycle will not start (cont.)

Automatic refill will not operate

Remedy

Refer to

Service

- ON/OFF switch for

testing procedures. See page 32

Refer to

Service -

Start switch for

testing procedures. See page 37

Refer to

Service -

Timer for testing

procedures. See page 39 or 42

Refer to

Service -

Dispense valve for

testing procedures. See page 22

Refer to

Service

- Control assembly

for testing procedures. See pages
23 thru 28

Check plumbing and shut-off valves.

(A) Direction of flow arrow must be
pointing towards brewer.

(B) Remove the strainer/flow con-
trol and check for obstructions. Clear
or replace.

Refer to

Service

- Solenoid valve for

testing procedures. See page 36

Refer to

Service

- Limit thermostat

for testing procedures. See page 31

Refer to

Service -

Overflow protec-

tion switch for testing procedures.
See page 33

Refer to

Service

- Level control board

for testing procedures. See page 29

Refer to

Service

- Electronic con-

trols for testing procedures. See page
23 thru 28

Probable Cause

3. ON/OFF switch

4. Start switch

5. Timer

6. Dispense Valve

7. Control Assembly (Electronic)

1. No water

2. Water strainer/flow control
(.750 GPM)

3. Solenoid Valve

4. Limit thermostat (Electro/
mechanical and Electronic)

5. Overflow protection switch

6. (A) Level control board & level
probe. (Electro/mechanical con-
trolled)

(B) Electronic controls

27040 011904