beautypg.com

Bunn DUAL TM (Serial # DUAL010000 - Up) 27040.0000F User Manual

Page 12

background image

Page 12

TROUBLESHOOTING (cont.)

Problem

Inconsistent beverage level in
server (cont.).

Consistently high or low beverage
level in server.

Dripping from sprayhead.

Water overflows filter.

Beverage overflows server.

Weak beverage.

Probable Cause

3. Dispense valve

1. Timer adjustment

1. Dispense valve

1. Bypass valve

2. Needle Valve

3. Type of paper filters

4. No sprayhead

1. Beverage left in server

2. Timer adjustment

3. Dispense valve

1. Type of paper filters

2. Coffee

Remedy

Refer to

Service -

Dispense valve for

testing procedures. See page 22

Adjust the timer as required to
achieve the recommended volume
for each brew cycle.

Refer to

Service

- Dispense valve

for testing procedures. See page 22

Refer to

Initial Set-Up

on page 5 step

#7. For test procedures see page 15

Refer to

Initial Set-Up

on Page 5

step #7

BUNN

®

paper filters should be used

for proper extraction.

Check sprayhead

The brew cycle should be started
only with an empty server under the
funnel.

Adjust the timer as required to
achieve the recommended volume
for each brew cycle.
Refer to

Service

- Timer for testing

procedures. See page 39 or 42

Refer to

Service

- Dispense valve for

testing procedures. See page 22

BUNN

®

paper filters should be used

for proper extraction.

A sufficient quantity of fresh drip or
regular grind should be used for
proper extraction.

27040 011904