Removal and Replacement:
1. Remove wires from the control thermostat.
2. Remove the thermostat capillary bulb by firmly

pulling up on the capillary tube at the tank lid. This
will disengage the grommet from the tank lid.

3. Remove the #8-32 slotted head screw holding the

control thermostat to the component bracket.

4. Slide the grommet to the line 7" above the bulb on

the new capillary tube.

5. Insert the capillary bulb through the hole in the

tank lid and press the grommet firmly and evenly
so that the groove in the grommet fits into the tank
lid.

6. Carefully bend the capillary tube so that the tube

and bulb inside the tank are in the vertical position.

NOTE - The capillary tube must be clear of any electri-
cal termination and not kinked.

7. Using a #8-32 slotted head screw fasten the con-

trol thermostat to the component bracket.

8. Refer to Fig. 8 when reconnecting the wires.
9. Adjust the control thermostat as required.

CONTROL THERMOSTAT (cont.)

FIG. 8 CONTROL THERMOSTAT

TERMINALS

BLU to Left & Right Ready Lights
BLU to RED Lead from Liquid Level Switch

BLK to BLK Lead of Contactor Coil
BLK to Left & Right Ready Lights