Bunn DUAL TM (Serial # DUAL010000 - Up) 27040.0000F User Manual
Page 21
Page 21
P780
SERVICE (cont.)
27040 032201
Removal and Replacement:
1. Remove wires from the control thermostat.
2. Remove the thermostat capillary bulb by firmly
pulling up on the capillary tube at the tank lid. This
will disengage the grommet from the tank lid.
3. Remove the #8-32 slotted head screw holding the
control thermostat to the component bracket.
4. Slide the grommet to the line 7" above the bulb on
the new capillary tube.
5. Insert the capillary bulb through the hole in the
tank lid and press the grommet firmly and evenly
so that the groove in the grommet fits into the tank
lid.
6. Carefully bend the capillary tube so that the tube
and bulb inside the tank are in the vertical position.
NOTE - The capillary tube must be clear of any electri-
cal termination and not kinked.
7. Using a #8-32 slotted head screw fasten the con-
trol thermostat to the component bracket.
8. Refer to Fig. 8 when reconnecting the wires.
9. Adjust the control thermostat as required.
CONTROL THERMOSTAT (cont.)
FIG. 8 CONTROL THERMOSTAT
TERMINALS
BLU to Left & Right Ready Lights
BLU to RED Lead from Liquid Level Switch
BLK to BLK Lead of Contactor Coil
BLK to Left & Right Ready Lights