beautypg.com

Bunn DUAL TM (Serial # DUAL010000 - Up) 27040.0000F User Manual

Page 11

background image

Page 11

TROUBLESHOOTING (cont.)

Problem

Water from tank is not hot (cont.).

Server warmer is not hot.

Spitting or unusual steaming from
sprayhead or airvents.

Inconsistent beverage level in server.

Probable Cause

6. Relay (Brewers with Recovery
Booster)

1. ON/OFF switch

2. Warmer element

1A. Control thermostat (Electro/me-
chanical)

1B. Control assembly (Electronic)

2. Triac assembly (Electronic)

3. Lime build-up

CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water conditions.
Excessive mineral build-up on stain-
less steel surfaces can initiate cor-
rosive reactions resulting in serious
leaks.

1. Strainer/flow control (.750 GPM)

2. Improper water pressure

Remedy

Refer to

Service

- Relay for testing

procedures. See page 34

Refer to

Service

- ON/OFF switch for

testing procedures. See page 32

Refer to

Service

- Warmer element

for testing procedures. See page 44

Refer to

Service

- Control thermo-

stat for testing procedures. See page
20

Refer to

Service

- Control assembly

for testing procedures. See page 23
thru 28

Refer to

Service

- Triac assembly for

testing procedures. See page 23 thru
28

Inspect the tank assembly for exces-
sive lime deposits. Delime as re-
quired.

(A) Direction of flow arrow must be
pointing towards the brewer.

(B) Remove the strainer/flow con-
trol and check for obstructions. Clear
or replace.

Check operating water pressure to
the brewer. It must be between 20
and 90 psi (138 and 620 kPa) .

27040 011904