beautypg.com

Operating instructions safety switch gp – EUCHNER GPxxx User Manual

Page 6

background image

Operating Instructions Safety Switch GP...

Figure 4: Dimension drawing GP...

40

30

31

3

∅ 4,1

∅ 5,1

V

M=0,6Nm

16

35

43

125

42

3,

5

32

31

22

16

M=0,6Nm

h

0,3 A

0,3 B

28

A

B

* Thr

ead (3x)

Insertion depth

Fixed positioning
for safety-related
applications
(screw M5)

* Thread according to

rating plate:
- M20 x 1.5
- NPT ½’’

Optional LED
indicator
(GP...528H/GP...538H only)

Necessary minimum travel + permissible overtravel

Approach direction

Actuator

Actuator

Standard

Overtravel

Horizontal (h)

28 + 2

28 + 7

Vertical (v)

29.5 + 1.5

29.5 + 7

Inser

tion depth

Order actuator separately

Figure 5: Min. door radii

Actuator type

Door radius min. [mm]

Actuator P-G...

1000

Actuator P-W...

1000

HINGED ACTUATOR P-OU...

90

HINGED ACTUATOR P-LR...

100

Hinged actuator P-LR / P-LRN

R > 100

Hinged actuator P-OU / P-OUN

12

26

20

35

28

+2

R > 90