Inspection and service

If damage or wear is found, the complete switch
and actuator assembly must be replaced.

Replacement of individual parts or assemblies
is not permitted!

No servicing is required, but regular inspection of
the following is necessary to ensure trouble-free long-
term operation:

correct switching function
secure mounting of components
dirt and wear
sealing of cable entry
loose cable connections or plug connectors.

Note:The year of manufacture can be seen in the
bottom, right corner of the rating plate.

Exclusion of liability under the following
circumstances

incorrect use
non-compliance with safety regulations
installation and electrical connection not performed
by authorized personnel.
failure to perform functional checks.

Subject to technical modifications; no r

esponsibility is accepted for the accuracy of this information. © EUCHNER GmbH + Co. KG

090205-06-10/10 (translation of the original operating instructions)

34

34

42

42

22

22

12

12

12

12

22

22

42

42

34

34

14

22

22

42

42

34

34

21

22

14

13

11

12

22

21

22

12

14

22

21

11

13

21

41

42

34

33

33

41

21

11

22

21

11

12

12

11

21

22

11

21

41

33

33

34

42

41

14

13

21

22

13

21

41

33

33

34

42

41

1

2

3

4

5

6

4

5

6

7

8

11

9

3

2

1

10

PE

Type

Switching contacts

GP.-528H...

1 NC contact + 1 NO contact

GP.-538H...

2 NC contacts

GP.-2121H...

4 NC contacts

GP.-2131H...

3 NC contact + 1 NO contact

GP.-3131H...

2 NC contact + 2 NO contact

Door closed

Door open

Plug connector

SR6

Plug connector

SR11

2.

1

2.

2

3

4

1.

1.

6

5

Ordinal numbers of
switching elements

2.

1.

1.

2.

3.

3.

4.

4.

6

8

5

7

4

3

2

1

Ordinal numbers of
switching elements

Terminal assignment with

plug connector

Connector
illustration

(view of safety switch

connection side)

(LED indicator with full wiring options, optional)

Figure 3: Switching elements and switching functions

EC declaration of conformity

The manufacturer named below herewith declares that
the product fulfills the provisions of the directive(s)
listed below and that the related standards have been
applied.

EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen, Germany

Directives applied:

Machinery directive 2006/42/EC

Standards applied:

EN 60947-5-1:2004 + Cor.:2005 + A1:2009
EN 1088:1995+A2:2008

Leinfelden, July 2010

Dipl.-Ing. Michael Euchner
Director

Duc Binh Nguyen
Authorized representative empowered to draw up
documentation

The signed EC declaration of conformity is included
with the product.

Technical data

Parameters

Value

Housing material

Reinforced thermoplastic

Degree of protection according to IEC 60529
GP1...

IP67

GP2...

IP65

Mechanical life

2x10

6

operations

Ambient temperature

-20 ... +80°C

Degree of contamination
(external, according

3 (industrial)

to EN 60947-1)
Installation position

Any

Approach speed, max.

20 m/min

Actuating force

10 N

Actuation frequency, max.

6700 / h

Extraction force

20 N

Retention force

2 N

Switching principle

Slow-action switching contact

Contact material

Silver alloy, gold flashed

Connection type
GP1...

Screw terminal

GP2...SR6

Plug connector SR6, 6-pin+PE

GP2...SR11

Plug connector SR11, 11-pin+PE

Conductor cross-section (rigid/flexible)
GP1...

max. 1.5 mm²

GP2...SR6

0.5...1.5 mm²

GP2...SR11

0.5 mm²

Operating voltage for

L060

12 - 60 V

optional LED indicator

L110

110 V

(GP...528H/GP...538H only)

L220

230 V

Switching voltage min.

12 V

at 10 mA
Switching current, min.,
at 24 V

1 mA

Short circuit protection (control

4 A gG

circuit fuse) acc. to IEC 60269-1
Conv. thermal current I

th

4 A

Utilization category

GP1.../GP2...SR6

GP2...SR11

according to EN 60947-1-5
AC-15

4 A 230 V

4 A 50 V

DC-13

4 A 24 V

4 A 24 V

Rated impulse

U

imp

= 2.5 kV

U

imp

= 1.5 kV

withstand voltage
Rated

U

i

= 250 V

U

i

= 50 V

insulation voltage
Rated short-circuit current

100 A

Reliability figures according to EN ISO 13849-1
B

10d

3 x 10