Step 3:
Holding by the base, remove the HPL lamp from its box.
Step 4:
Align the flat sides of the lamp base with the retention brackets on either side of the
socket as shown in
Figure 3
.
Step 5:
Push down on the lamp base until the lamp seats firmly. When properly installed, the top
of the lamp’s base will be even with he top edges of the retention brackets.
Step 6:
Press lamp retaining clip across lamp base to secure.
Step 7:
Reconnect the Earth continuity cable. Reinstall the lamp housing by aligning the bolt hole
and tightening the knurled bolt.
Focus knob positioning
To adjust focus knob tension, loosen or tighten the focus knob screw. See
Figure 4
.
C A U T I O N :
Use caution when installing or replacing any lamp.
When installing/replacing lamp, be sure to point the lamp away from your face and
away from others before inserting it firmly into the assembly.
This may prevent injuries if the lamp should break.
N o t e :
To avoid premature lamp failure, do not touch the lamp glass. If you do, clean it
carefully with isopropyl alcohol and a clean lint-free cloth. Allow to dry before
operation.
C A U T I O N :
Improperly installed lamps cause premature lamp failure and socket problems.
C A U T I O N :
Lens rotation knob does not rotate 360°. Do not attempt to exceed limit.
INCORRECT
CORRECT
Focus knob in
flood position
Figure 4
Focus knob in
spot position
45° field angle
25° field angle
Focus knob
screw