Cooling Fan Filter Cleaning



Cooling fan filters should be inspected at a minimum every six months; more frequently

if fixtures are powered on for more than four hours per day



Use a vacuum cleaner to remove dust from each fan filter



In dusty environments or conditions involving the use of smoke machines, clean the

filters as follows:

Using fingernail or small flat-blade screwdriver, remove fan filter cover by prying
under one of the two locking tabs

Carefully remove foam fan filter from fan assembly

Gently wash foam fan filter in a solution of mild dishwashing solution and water

Thoroughly rinse each foam fan filter in clear water

Pat dry or air-dry filters

After filters are completely dry, reinstall by inserting them into fan assembly

Reattach the filters to the fixture

N o t e :

No user-serviceable parts are inside.

Fuse Capacities

All Selador Fixtures use 3AG 250V 32mm x 6mm fuses. Use the following capacity fuses

for all Selador fixtures.

Fixture Size

Fuse Value

11

2 A

21

4 A

42

8 A

63

10 A