8 i/os, 1 digital input interfaces, I/os 4.8.1 – ElmoMC SimplIQ Digital Servo Drives-Cello Installation Guide User Manual
Page 67: Digital input interfaces

Cello Installation Guide
Technical Specifications
MAN-CELIG (Ver. 1.602)
67
4.8 I/Os
The Cello has:
10 Digital Inputs
5 Digital Outputs
2 Analog Input
4.8.1 Digital Input Interfaces
Feature
Details
Type of input
Optically isolated
Single ended
PLC level
Input current
* I
in
= 2.2 mA for V
in
= 12 V
Input current for high speed
inputs
* I
in
= 4.4 mA for V
in
= 12 V
High-level input voltage
12 V < V
in
< 30 V, 24 V typical
Low-level input voltage
0 V < V
in
< 6.5 V
Minimum pulse width
> 4 x TS, where TS is sampling time
Execution time (all inputs):
the time from application of
voltage on input until execution
is complete
If input is set to one of the built-in functions — Home, Inhibit,
Hard Stop, Soft Stop, Hard and Soft Stop, Forward Limit,
Reverse Limit or Begin — execution is immediate upon
detection: 0 < T < 4 x TS
If input is set to General input, execution depends on
program. Typical execution time: ≅ 0.5 msec.
High-speed inputs - minimum
pulse width, in high-speed mode
(IN5 - IN6)
T < 5 µsec
Notes:
Home mode is high-speed mode and can be used for
fast capture and precise homing.
High speed input has a digital filter set to same value
as digital filter (EF) of main encoder.
Highest speed is achieved when turning on
optocouplers.