Chapter 4: technical information, 1 physical specifications, 2 technical data for the 400 v type – ElmoMC Gold Line Digital Servo Drives-Gold DC Trombone User Manual
Page 9: Chapter 4, Technical information, Physical specifications, Technical data for the 400 v type

Gold DC Trombone Installation Guide
MAN-G-DCTROIG-EC (Ver. 1.900)
|Physical Specifications
9
9
Chapter 4:
Technical Information
4.1 Physical Specifications
Feature
Units
All Types
Weight
g (oz)
650 g (22.9 oz) for standard L shape
1100 g (38.8 oz) for L shape fins and fan
Dimensions
mm (in)
105 x 140 x 47 (4.13" x 5.51" x 1.85")
Mounting method
Panel / Wall Mounted
4.2 Technical Data for the 400 V Type
Feature
Units
6/400
12/400 16/400 R17/400 R22/400
Minimum supply voltage
VDC
A, H, S, or T in P/N*: 50
0 or 1 Option in P/N: 100
Nominal supply voltage
VDC
325
Maximum supply voltage
VDC
400
Maximum continuous power
output
kW
2
4
5
5.5
7
Efficiency at rated power (at
nominal conditions)
%
> 98
Auxiliary supply voltage option VDC
18 V to 30 V
Only for Control Supply A/H/S/T Option Models
Auxiliary power supply
VA
7
Continuous current limit (Ic)
Amplitude sinusoidal/DC
trapezoidal commutation
A
6
12
16
17
22
Sinusoidal continuous RMS
current limit (Ic)
A
4.2
8.5
11.3
12
15.5
Peak current limit
A
2 x Ic
No peak