Installation Step 2: Communication Address Setup
An RF Controller controls one 8294-06, 8294-06 EXT, or 8394-07 monitor. The controller is digitally
encoded with a security code ensuring that it does not accidentally control the wrong monitor. The
receiver has a matching decoder and security code that instantly decodes and interprets commands.
The security code is a 15-bit selectable code that is set on both the remote transmitter and receiver.
The 8294-06, 8294-06 EXT, and 8394-07 monitors are tested and shipped with a security code based
upon the monitor serial number, ensuring each monitor leaves the factory with a unique code assigned
to it. The security settings will normally not need to be changed. In the case of a lost transmitter or
replaced control board, contact Elkhart Brass.
Danger:
Using two W.E.T. monitors with the same security code may cause the
inadvertent control of the wrong monitor, resulting in possible property damage and
injury to personnel. Using the factory specified codes will help prevent this.
Caution:
Do NOT pinch wires when attaching back panel to front panel of the
handheld enclosure. Ensure all O-rings and gaskets are properly installed when closing
the receiver or transmitter enclosures.
Important:
The RF Receiver/Control Module and all transmitter communication
addresses have been factory set. They should not require any additional address setup.