Caution – Elkhart Brass Copperhead 8593-04 Monitor User Manual
Page 12
12
Installation Step 4: System Programming
Programming Horizontal Limits & Stow Position
The 8593-04 Copperhead RF monitor must show H2 limits relative to mounting
flange. The monitor is shipped from the factory with horizontal limits at 180° (90°
left and 90° right of the straight ahead position). The vertical limits are provided by
magnets placed in the monitor at assembly and are not adjustable.
NOTE: All programming steps must be completed. Otherwise the changes will not be
stored to permanent memory.
Remove the cover from the RF Receiver/Control Module located on the monitor.
Supply power to the monitor.
Hold the Red Programming Button on the control module board until the programming LED
flashes on (approx. 5 seconds).
To set the left travel limit, rotate the monitor left until it has reached the mechanical stop.
Quickly press and release the Red Programming Button. The status LED will flash once to
acknowledge the new limit position.
To set the right travel limit, rotate the monitor right until it has reached the mechanical stop.
Quickly press and release the Red Programming Button. The status LED will flash twice to
acknowledge the new limit position.
To set the horizontal stow position of the monitor, move the monitor left or right to the desired
position. Quickly press and release the Red Programming Button. The status LED will flash
rapidly several times to acknowledge the new stow position. NOTE: The stow position must be
between the right and left limits that were just programmed in the previous two steps. It is not
recommended to set the position right at the maximum right or left travel limit.
To choose the vertical stow position of the monitor, set switch A position 1 “ON” for stow up, or
switch A position 1 “OFF” for stow down (Receiver only). NOTE: The vertical stow position will
either be all the way up or all the way down, nowhere in between.
Remove power from the monitor for a minimum of 5 seconds. Reapply power and operate the
monitor to verify that the travel limits are at the correct positions, and the monitor stows
correctly. If not, follow the steps above to reprogram the limits.
Figure 3: SW1 Programming Button
Caution:
To prevent damage to the monitor controller, keep all metallic objects away
from the receiver circuit board while it is energized. Ensure all O-rings and gaskets are
properly installed when closing receiver enclosure.
DS5
DS2
B
A
DS1
SW4
SW1
DS4
P2
DS3
P3
DS6
P1
P4
SW2
SW3
Red Programming
Button (SW1)
Programming
Status LED (DS5)