transmission.
Baud rate has to be set before proceeding to other settings.
7.1 PC (COMPUTER) MODE
Weight status and data are sent under the PC (Computer) Mode). Data is
transmitted in ASCII code. Data format is listed on below table.
DATA BIT
DESCRIPTION
1~2
MOTION STATUS
US = UNSTABLE
ST = STABLE
3
COMMA SEPARATION
4~5
NET/GROSS
NT = NET WEIGHT
GS = GROSS WEIGHT
6
SIGN (Sign of weight reading)
Positive = space. Negative = minus (-)
7~13
WEIGHT VALUE
7-character string containing the current weight including
location of decimal point.
If there is no decimal point, then the first character is a
space.
14
COMMA SEPARATION
15~16
UNIT
kg = kilogram
g_= gram (_ = blank space)
lb = pound
17
Cr
18