Chapter 3 Operation
3.1 POWER ON AND AUTO ZERO-SETTING
3.1.1 The indicator will perform countdown self-checking when turned on. Then it will enter weighing
mode.
3.1.2 When powered on, if loading weight on the scale deviates from the zero point, but still within
zero set range, the indicator will set zero automatically; if it is out of range, it is necessary to
adjust the zero point or recalibrate or reset.
3.1.3 Press UNIT button to select your weighing unit. There is indication on the readout panel
showing the current weighing mode.
3.2 MANUAL ZERO SETTING
3.2.1 In weighing mode, you can press [Zero] anytime to zero the readout.
3.2.2 If the displayed value deviates from zero point, but still within zero-range, pressing [Zero] key is
available. Otherwise, [Zero] key is invalid. (In this status, please recalibrate or reset zero
parameters)
3.2.3 Zero function works only when the STAB sign is on.
3.3 TARE FUNCTION
When Indicator is in weighing mode, press the [Tare] key, the indicator will deduct the displayed weight
value as tare weight. Then indicator displays net weight as “0”, and Tare sign is on.
3.4 COUNTING FUNCTION (WHEN F3 KEY=1)
Sampling: Tare the weight of any container that is used and leave the container on the scale. Place
samples on the scale. The quantity of the samples should match the options for the pre-set
values: 10, 20, 50, 100 or 200 pieces. Press [MOD] key and the screen will show “P10”, which
means the requirement of the sample size. If the sample quantity on the scale is not 10 pieces,
press [TARE] key to select the according sample size. Press [FUN] key to confirm.
Counting: Remove the samples from the container and place the items need to count into the container.
You can see the counts on the display. Press [FUN] key to view Unit Weight (in gram), Counts
and Total Weight. You may exit counting mode anytime by pressing [MOD] key.
3.5 ACCUMULATING FUNCTION (WHEN F3 KEY=2)
In weighing mode, press [FUN] key to enter accumulating mode. Place the first item onto the scale
and wait until the STAB sign on. Press MOD key to store the weight into memory. Remove the
first item and place the second item onto the scale then repeat the previous procedure. Maximum
loads for one accumulating is 200.
Clear the scale platform and press [FUN] key to view the number of loads and total weight. Press
[ZERO] key to clear the memory.