Floor / Pallet Scale

- 11 -

Chapter 6 Recharge Battery

6.1 Turing on the AC power, the indicator will recharge the battery automatically. So if you don’t use

battery frequently, you should take battery out.

Note: red end is +, black end is -. Wrong connection will destroy indicator.

Note: The built-in battery should be fully charged before it is used for the first time.

6.2 Only when you turn off the AC power, and push start key, battery works. Displaying [LouoL] means

the insufficient of voltage, it needs charge.

6.3 When you use the battery first time, you should charge the battery for 20 hours in order to prevent

low voltage resulted from the self leakage of the battery.

6.4 If you don’t use battery for a long time, you should charge the battery for 10-12 hours for each 2

month to prolong using life of battery.

6.5 The battery is easily exhausted products. And it is not granted free guarantee.

Chapter 7 Maintenance

7.1 To guarantee indicator clarity and using life, the indicator shouldn’t be placed directly under

sunshine and should be set in the plain space.

7.2 The indicator can’t be placed into the place where the dust pollution and vibration are serious.
7.3 Load cell should connect with indicator reliably, and the system should be well connected into

ground. The indicator must be protected from high electrical field and high magnetic field.

In order to protect the operator, indicator and relevant device, you should mount lightning rod in

thunderstorm frequently happening area.

Load cell and indicator are static sensitive device, you must adopt anti static measures.

7.4 It is strictly forbidden to clean the case of indicator with intensive solvents (for example: benzene

and nitro oils)

7.5 Liquid and conducting particle should not be poured into the indicator, otherwise the electronic

components will be damaged and electric shock is likely to happen.

7.6 You should cut off power supply of indicator and relevant device before you pull-in and out the

connecting line of indicator and external device.

You must cut off power supply of indicator, before pulling out connecting line of load cell.

7.7 During operation, if trouble occurs, operator must pull off the power supply plug immediately, and

user should return this indicator to our company for repair. Non-weighing manufacturer should not
repair it, or by yourself, otherwise further destruction may happen.

7.8 The storage is not granted the free repair guarantee, because it is easily exhausted products.

In order to prolong using life, please charge the cell fully before using it. If you don’t use the

indicator for a long time, you must charge the cell every two month and for eight hours/each
charging time.

Moving or installation must be carefully taken and must avoid strong vibration, impact and bump
in order to protect the storage cell from being damaged.

7.9 From invoice date, the indicator has a one-year free repair period. If any non-artificially obstacle

about the indicator happens under correct using conditions within this period, the user is allowed
to send the product with its guarantee card (of the correct number) back to our corporation for free
repair. The indicator shouldn’t be taken apart, otherwise free guarantee will be cancelled.