beautypg.com

49 appendixes – Dascom 7106 User Guide User Manual

Page 49

background image

49

Appendixes

Specifications

Item

Description

Power (standards)

100V version

100V, 50/60Hz (Japan)

120V (-10%+6%), 2.5A, 60Hz (U.S.A., Canada)
UL60950-1, CSA No. 950, FCC Part 15 Subpart B (Class A)

220V version

220V-240V (-10%+6%), 1.2A, 50/60Hz (Europe)
EN60950-1, EN55022 (Class A), EN55024, EN61000-3-2,
EN61000-3-3

Environment

Operating temperature

Operating temp. 0 to 40°C, humidity 30 to 80%, condensation free

conditions:

(Conditions: ventilation, and natural convection)

Storage temperature

Temp. –20 to 60°C, humidity 5 to 85%

conditions:

(Conditions: ventilation, and natural convection)

External dimensions

Approx. 231(W) X 289 (D) X 186 (H) mm

9.1(W) X 11.4 (D) X 7.3 (H) inch

Weight

Approx. 3.5 kg (7.7 lb.)

Accessories

Test label media, CD-ROM (User’s Manual), Quick start guide
Head cleaner, Power cord, Media holder bar and Media holder guide

Option

Auto-cutter unit, Peeler unit, IEEE1284 Parallel interface board, Ethernet
interface board and Wireless LAN interface board

*1: Options can be separately purchased.
*2: When a media pitch of less than 1 inch is used, activate the “Small Media Adjustment” setting in the “Page Setup.”
*3: The OCR font may have a low recognition rate according to the reader.
*4: It is equipped with UFST

TM

and TrueType

TM

rasterizer that are licensed from Agfa Corporation.

TrueType

TM

is a trademark of Apple Computer.

UFST

TM

and TrueType

TM

rasterizer are licensed from Agfa Corporation.

UFST

TM

is a trademark of Agfa Corporation. TrueType

TM

is a trademark of Apple Computer.

*5: "PC866U Ukraina" is available for Datamax

®

emulation only.

*6: Datamax

is a registered trade mark of Datamax Bar Code Products Corporation.

*7: Zebra

®

is a registered trade mark of ZIH corp.

0

5

35

30

40

80

40

Humidity %

Operating assurance temperature
Printing assurance temperature

Temperature °C

-20

60

5

85

Humidity %

Temperature °C

Conditions assuring operation and printing

Storage assurance temperature

Unit: mm (inch)

Approx. 231 (9.1)

Approx. 289 (11.4)

Approx. 186 (7.3)