Chapter 3: system preparation and specifications, 250 m, 120 m – Comelit MT VIP SYSTEM User Manual
Page 14
![background image](/manuals/556761/14/background.png)
14
Chapter 3: System preparation and specifications
A Max.
0.5 mm2 (Ø 0.8 mm - AWG 20)
10 m
0.5 mm2 (Ø 0.8 mm - AWG 20)
Comelit art. 4576-4578
10 m
1 mm2 (Ø 1.2 mm - AWG 17)
25 m
1 mm2 (Ø 1.2 mm - AWG 17)
Comelit art. 4577
25 m
1 mm2 (Ø 1.2 mm - AWG 17)
25 m
1.5 mm2 (Ø 1.4 mm - AWG 15)
40 m
2.5 mm2 (Ø 1.8 mm - AWG 13)
60 m
Connection distances from power supply unit art. 1395 to external unit art. 3331
1395
Connection distances between external unit art. 3331 and Switch art. 1440
The connection distance varies depending on the port used on Switch art. 1440.
Art. 1440
10 Mb
250 m
Art. 1440
100 Mb
120 m
Using the 10 Mb port
Using the 100 Mb port
Connection distances between 2 Switches art. 1440
The connection distance varies depending on the ports used on Switches art. 1440.
Art. 1440
10 Mb
250 m
Art. 1440
10 Mb
Art. 1440
10 Mb
250 m
Art. 1440
100 Mb
Art. 1440
100 Mb
250 m
Art. 1440
10 Mb
Art. 1440
100 Mb
120 m
Art. 1440
100 Mb
Connection distances