background image

Programming

12

MC22 -GB-v1.01

itSp
Meaning:

initial set point, it is the set point used by the programmer during the
“idle” state

Range:

OFF, and then from 0°C – 1500°
The OFF value means that the control output(s) will be disabled
during the “idle” state; at program start up the setpoint will be
aligned to measure value and then ramps to SP. 1.

Available:

always

Alterable:

only when the programmer state is idle or, for program 1-2-3, if the edit is
enabled


Sp. 1
Meaning:

target set point of the first segment

Range:

0°C

– 1500°C

Available:

always

Alterable:

only when the programmer state is idle and, for program 1-2-3, the edit is
enabled


rr. 1
Meaning:

ramp rate to SP1.

Range:

from 0.1 to 12°C (Engineering units (°C) per minute)

Available:

always

Alterable:

only when the programmer state is idle and, for program 1-2-3, the edit is
enabled


TH. 1
Meaning:

time held (dwell) at SP1

Range:

from 0 min to 99 h 59 min

Available:

always

Alterable:

only when the programmer state is idle and, for program 1-2-3, the edit is
enabled

Sp. 2
Meaning:

target set point of the second segment

Range:

End, and then from 0°C – 1500°C

The End value, selectable from the second to the fourth set point, is used to
end the program before the last

– fourth - segment. This avoid to edit

unnecessary parameters for programs shorter than four segments.

Available:

always

Alterable:

only when the programmer state is idle and, for program 1-2-3, the edit is
enabled


Then rr. 2 , tH. 2, Sp. 3 , rr. 3 , tH. 3 , Sp. 4 , rr. 4 , tH. 4 as above.