beautypg.com

Raid 1 – CalDigit RAIDShield User Manual

Page 36

background image

35

35

RAID 1:

RAID 1 is commonly referred to as Disk Mirroring, Disk Shadowing or Disk Duplexing as all data is duplicated across
both disks. RAID 1 can only be performed with two hard drives (with four drives, RAID 0+1 is configured automatically).
As data is identical on both disks, storage capacity is that of the smaller disk. RAID 1 has poor performance for write
operations but very high performance for read intensive operations.

RAID 1: Mirroring

Characteristics: Recommended

use:

Better Read transaction rate then single disks,
same Write transaction rate as single disks.

100% redundancy of data means no rebuild of
data is necessary in case of disk failure, just a
copy to the replacement disk.

All the disks have the same data.

RAID level 1 requires two drives.

Storage capacity = Capacity of smaller disk

Accounting

Payroll

Financial

Any application
requiring high
availability

Arrangement of data blocks saved on a Level 1 array