Problem
Possible Causes
Solutions
Slow Drift
Down
1. Mechanical safety locks not
engaged
2. Powerpack lowering valve
contamination
3. Hydraulic system leaks
1. Raise lift to engage all safety locks then lower
lift and confirm all safety locks are engaged
2. Back flush powerpack by opening manual
over-right valve. Engage "up" switch and down
lever at the same time and run approximately
10 seconds
3. Check cylinder and all fittings for any hydraulic
oil leak
Lift Going
Up Out of
Level
1. Cable(s) out of adjustment
1. re-adjust cables - Call service technician if
problem persists
Anchors
Will Not
Stay Tight
1. Holes drilled oversize
2. Concrete floor thickness or holding
strength not sufficient
1. Relocate lift using the correct bit to drill holes
2. Break out old concrete and re-pour new
foundation per lift installation instruction
Replace all worn or broken parts and components only with
manufacturer approved/supplied parts and components
Replacement parts may be purchased from your local lift supplier or the
manufacturer at 1 - 800 - 688 - 6359