beautypg.com

3 general maintenance, Notice – Autoquip SUPER TITAN DOUBLE LONG User Manual

Page 35

background image

35

6.2.5 Oil Capacity

Oil capacity varies between models. Capacity is a minimum 10 gallons.

Use approved fluids only. Use of unauthorized fluids may cause damage
to seals and hosing.


Do Not Use:

 Automatic Transmission Fluid (ATF)

 Hydraulic Jack Oil
 Hydraulic

Fluids

 Brake

Fluids

6.3 General Maintenance

6.3.1 Hydraulic Cylinder Repair

6.3.1.1. Cylinder Plunger Removal

1. Raise lift to its full height and engage

maintenance devices. See “Maintenance
Devices”.


2. Disconnect electrical power to lift. Follow lock

out-tag out procedure.

3. Disconnect cylinder hose at power unit end and

insert into reservoir oil-fill hole.


4. Remove thrust angle clips (A) from ram end of

cylinder and force ram slowly back to its fully
closed position to push oil back into reservoir.


5. Remove cylinder hose from reservoir fill hole and

pull ram (B) all of the way out of cylinder. Support
it carefully so that it does not drop when it clears
cylinder end. Lay it down in a safe, clean place.
Some oil may drip from the end of cylinder so
have waste cloth or paper beneath lift to protect
floor.










NOTICE

This manual is related to the following products: