beautypg.com

Atop Technology EH2005-Fm User Manual

Page 3

background image

Atop Industrial Unmanaged Ethernet Switch

EH2006 / EH2005-Fs / EH2005-Fm

Hardware Installation Guide Version 1.4

Copyright c 20 10 ATOP Technologies, Inc.

All rights reserved

- 2 -

4. Hardware Installation

Step1: Connect to Power

 Prepare suitable DC 9~30V power source and connected to EH switch by 3-pin

Terminal blocks.

 You can connected two DC input for power auto-backup need.
 Check P1/P2 LED for correct power source, everything is OK if the LED(s) was

lighted

Step2: Connect to Network Device by Ethernet

 Connected your device by standard UTP/STP cable with RJ-45 connectors to EH

switch.

 The LINK LED will be lighted if the Ethernet connection was linked.
 It is indicated and blinked if data was transfer by EH switch hub.


UL Notice for Power supplier

All the series of EH products are intended to be supplied by a Listed Power Unit
marked with ¡LPS¡, ¡Limited Power Source¡ or ¡Class 2¡ and output rate 9-30VDC,
0.6A. Or, use the recommended power supply in ¡Optional Accessories.

5. LED Indicators

There are four LED indicators located at the front panel of EH series.

Name

LED

Status

Description

Off

Both P1 and P2 on or off

ALM

Green

On

Either P1 or P2 on

Off

Power input 1/2 is not plugged yet

P1/P2 Green

On

Power status is Ready

Off

Link is Boren or Cable not be plugged

Green

Blink

Traffic be indicted for data transfer

Off

10M rate be active

RJ45

Yellow

On

100M rate be active

Off

No data be transmitted

Data

Blink

Working when data transmitted

Off

No media be available

Fiber
SC/ST

Link

On

Working when media was ready

7. Configuration and Setting Methods

Any settings or configurations are unnecessary.