beautypg.com

Polar neon, bulk reels – American Lighting PLR-NF Series User Manual

Page 2

background image

1. Determine the required length for flexible light.

2. Cut the Polar Neon squarely at the nearest series increment cut

mark using a sharp rope light cutting tool or shears.

NOTE: Polar Neon is wired in series parallel. Cutting anywhere

other than the end/beginning of a series increment will result in a loss

of light. (see Figure 2)

3. Holding the smooth pins of the power pin with a pair of pliers, line up

the barbed pins with the two wires of the flexible light. Push barbed pins

into Polar Neon until flush, being sure to make solid contact with the

flexible light’s internal wires. (see Figure 3).

4. Slide the shrink tube over the assembly and onto the Neon Polar Neon.

5. Push the power cord sheath onto the assembly until fully seated.

6. Slide the heat shrink tube over the power cord sheath so that it is

centered over the junction of the Polar Neon and the power

cord sheath. (see Figure 4).

7. Attach end cap to other end of flexible light to cover exposed dead end.

CONNECTING POWER CONNECTION KIT (See Figures 2, 3, and 4)

NOTE: Do not exceed 150.9’ maximum run distance in any single run.

MOUNTING:

1. Make mounting clips using cut pieces of track (PLR-NF-TRACK-4, sold separately) or for straight line

applications, use PLR-NF-TRACK-4 mounting track; or use a combination of methods. PLR-NF-CHAN-1M

aluminum channel is also available (sold separately).

2. Make sure that the distance between any two parallel runs of lighting are at least 1/2” apart.

3. Gently press flexible light into track or clips so that it snaps into place.

PROP 65 WARNING:

Handling the coated electrical wires of this product exposes you to lead, a chemical known to the State of

California to cause cancer, birth defects, and other reproductive harm. Wash hands after use.

RV1433

WWW.AMERICANLIGHTING.COM

Polar Neon, Bulk Reels

Installation instructions for PLR-NF Series

10-10 AMERICAN LIGHTING

120V, 60

HZ MAX

LENGTH

150.9

FT.

Figure 2

Figure 3

Figure 4

Polar Neon

Power cord sheath

Heat shrink tube

Polar Neon and

power pin assembly

Power pin

Series increments are marked on

the side of the housing as shown.

Line up the barbed ends of the

power pin with the wires inside and

push pin in to make solid contact.

Trim off any wires that protrude from the

Polar Neon to prevent a short.