American Lighting EP5 Series User Manual
5” e-pro series led recessed downlight, Installation instructions for ep5 series
measure the diameter of the housing. The recessed housing must have a minimum measured inside
diameter (opening) of 5”; maximum diameter 5-3/4”; minimum clearance of 4”. See Figure 1.
Do not make or alter any open holes in a wiring enclosure, nor in any electrical components during kit
Do not use these products in luminaires located where elevated ambient temperatures exist.
determine whether power supply is 120V AC at the luminaire before installation.
WARNING: To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other
sharp objects.
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS
INVOLVED.
THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A FLUORESCENT LUMINAIRE WHERE THE
SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION.
Each fixture includes an attached lead wire with a 120V plastic connector (for use with either a GU24 or E26
adaptor); an E26 adaptor; an insulating foam ring and a set of attached torsion springs. See Figure 1.
FUTURE LAMP REPLACEMENT & GU24 ADAPTORS
EP5 Series models and GU24 adaptors (item #AL-GU24) are
120V plastic connector
for use with either a
GU24 or E26 adaptor
E26 adaptor
GU24 adaptor
Denver, CO 80231 • www.americanlighting.com
© 2012 American Lighting, Inc.
RV1247 Page 1 of 2
Torsion springs
available from American Lighting, Inc. Contact (800) 880-1180 or visit www.americanlighting.com to find a local distributor.
Figure 1
Insulating foam ring
These products may represent a possible shock or fire hazard if improperly installed or attached in
any way. Products should be installed in accordance with these instructions, current electrical codes and/or
the current National Electric Code (NEC).
5” E-Pro Series LED Recessed Downlight
Installation instructions for EP5 Series
WARNING:
CAUTION - To reduce risk of fi re, electric shock or inju ry to persons:
1. Make sure that the electrical power to the fixture is disconnected prior to any installation or retrofit.
3.
4.
Use with 5”recessed cans (recessed housings) only. Do not attempt to alter for other sizes or purposes.
For best dimming results, use standard incandescent wall dimmers in a branch circuit this is supplied with 120V AC
power. Check dimmer manufacturer’s specifications to confirm whether minimum loads apply. Each fixture = 9.5W
2. This light is suitable for damp locations.
5
6-1/2” (165 mm) Dia.
3-1/2” (88 mm)
clearance required