American Lighting T30 Series User Manual
Led wall pack
©2014 American Lighting
Denver, CO 80231 Made in China
www.americanlighting.com
LED WALL PACK
Installation instructions for WP-T15 & T30 Series
RV-1435
Figure 1
READ ALL OF THESE INSTALLATION INSTRUCTIONS BEFORE INSTALLING THE FIXTURE. FAILURE TO FOLLOW
INSTALLATION INSTRUCTIONS AND ALL APPLICABLE ELECTRICAL CODES WILL VOID THE PRODUCT WARRANTY.
WARNING:
These products may represent a possible shock or fire hazard if improperly installed or attached in any way.
Products should be installed in accordance with these instructions, current electrical codes and/or the
current National Electric Code (NEC).
WARNING:
Disconnect supply power from the source prior to installation. This product must be installed by a person
familiar with the construction and operation of the product and the hazards involved, and in accordance with
current electrical codes and/or the current National Electric Code (NEC). Consult a local licensed electrician if
you are not sure about the installation. To reduce potential of electric shock, fixture must be grounded.
The electrical input voltage of this product is 120-277V AC. The installer must determine whether power
supply is in the range of 120-277V AC at the luminaire before installation.
Do not mount or support these fixtures in a manner that can cut the outer jacket or damage the wire
insulations. Do not restrict fixture ventilation. Do not cover fixtures with insulation or any material that will
impede air flow around and heat dissipation of the fixtures.
APPLICATION / USE:
This product is suitable for use in wet locations and designed for surface mounting only. This fixture is suitable for
installation where ambient temperatures do not exceed 104˚F (40˚C) during anticipated hours of fixture
operation. Minimum ambient operating temperature is -22˚F (-30˚C).
INSTALLATION:
Disconnect supply power from the source prior to installation.
Installation requires #2 Phillips & Flathead Screwdrivers
1. Remove old fixture if applicable.
2. Open the lens assembly and then remove the front housing
assembly. DO NOT touch the LEDs. DO NOT drop or mishandle the
front housing assembly. (Figure 1)
3. Prepare the back plate for mounting by drilling or knocking out the
appropriate holes. (Figure 2)
4. line up the back plate in desired location and mount securely. (Two
gaskets are provided for weather tight seal between template and
junction box.)
5. Complete wiring to the power source and grounding wire.
6. Reinstall the front housing.
ADDITIONAL SAFETY MEASURES:
1. LEDs are not serviceable. Do not attempt to open the fixture or LED compartment.
2. LEDs are bright. Do not look directly into fixture.
3. Not intended for recess mounting in any type of installation.
4. Do not use with wall dimmers or in dimming circuits.
Note: These instructions do not cover all details or variations in equipment nor do they
provide for every possible situation during installation, operation or maintenance.
MOUNTING:
The back plate has a cast-in drill and knock-out template to match
any standard recessed junction box, three 5/16” knockouts for
mounting holes (A) and three 1/2” NPS tapped holes (D) for surface conduit, photo control.
Refer to Figure 2 to locate these as needed:
A - 5/16” dia. knockouts
B - 9/16” dia. knockouts
C - Knockouts for #10 screw
D - 1/2” NPS tapped holes
IMPORTANT:
To weather-proof your outdoor installation, seal all holes in fixture
housing with silicone sealant.
TEMPLATE
GR
GR
GND
A
A
A
C
B
31/4" OCT.BOX
4" OCT. BOX
D
D
D
Figure 2