American Lighting LWX Series User Manual
Led linkworks
WARNING: These products may represent a possible shock or fire hazard if improperly installed or attached in
any way. Products should be installed in accordance with these instructions, and with current electrical codes
and/or the current National Electric Code (NEC).
Warning: To avoid electric shock, disconnect power prior to installation.
Warning: This product is for use in horizontal installations only. Do not mount vertically! Failure to do so
will damage the fixture and may cause a fire hazard.
Save these instructions.
Use only with the power cord, linking connectors and linking extensions recommended by the factory.
Alteration of the fixture or accessories will void the warranty.
Not designed for use with dimming circuits.
For indoor installations only. Suitable operating temperature is -4°F to 104°F (-20° to 40°C); suitable for use in
environments with 0-80% humidity. Using this product in environments outside of these ranges will impact LED
life negatively.
For 120V, 50/60Hz input power applications only.
Unpack the fixture and inspect for any damage. If there is any damage to the power cord, housing or end
connections, do not install.
NOTE: DO NOT CONNECT MORE THAN 75 LWX-24 SERIES FIXTURES; OR MORE THAN 38 LWX-48 SERIES FIXTURES;
OR MORE THAN 384 WATTS TOTAL WHEN LWX-24 AND LWX-48 SERIES ARE INTERMIXED.
LWX-24 SERIES = 120V AC, 50/60Hz, 9 watts (0.075A) per fixture
LWX-48 SERIES = 120V AC, 50/60Hz, 18 watts (0.15A) per fixture
The use of chemicals or solvents may degrade the housing finish or its protective coating. Use only a mild soap
and/or slightly damp soft cloth to clean the fixture. Harsh chemicals will damage the lens and/or fixture. Do not
wipe the fixture with a rough cloth that may scratch the finish or the lens.
IMPORTANT SAFETY INSTRUCTIONS:
This portable luminaire has a polarized plug (one blade is wider than the other) as a safety feature to reduce the
risk of electric shock. This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician. Never use with an extension cord unless the
plug can be fully inserted. Do not alter the plug.
WARNING:
Fixtures should NOT be installed or interconnected with power attached. Do not connect to power
while fixture is in the packaging. However, when installation is complete, check that all fixtures light up properly
when power is applied. If not, note any unlighted areas and disconnect power to correct the issue. Most of the
time, if a fixture or set of fixtures will not light, it is due to power connections not being firmly and fully
connected.
Installation:
1. Determine desired locations for set of LED Linkworks allowing an additional 3” for power cord and end cap at
plug-in (live) end.
2. Also, consider locations of any extensions, Xs or Ts. Note: To determine locations of clips when accessories
are involved, plan ahead for cords and fittings so that each component has enough room to plug into LED
Linkworks fixture body.
3. Attach two mounting clips per fixture for each location using screws included or suitable fasteners for the
mounting surface. Clips should be located about 1/3 in from either end of fixture.
CONTINUED ON REVERSE
LED Linkworks
Installation Instructions for LWX Series
RV-1304
©2013 American Lighting
Denver, CO 80231 Made in China
www.americanlighting.com