Additional safety measures – American Lighting ALC Series User Manual
Page 2

www.americanlighting.com
LED Complete 120V Under Cabinet Light
Installation Instructions for ALC Series
Additional Safety Measures:
1. Do not look directly at LED light source.
2. Do not touch the LEDs.
4. Do not operate without end connector cover(s) in place for any molex ports/connectors not in use.
5. There are no serviceable parts inside LED module.
6. WARNING!
7. Suitable for indoor dry locations only.
8. This product is suitable for use in dimming circuits. For best results (5-100% lighting control), use Lutron DV600P,
S600, DVCL-153P or TC-600P type dimmers (www.lutron.com).
from curtains and other combustible materials.
Suitable for indoor dry locations only.
Figure 9
Cable connector
Knockouts
Figure 8
Remove screws at each end
Supply wires connection via housing knockouts
Note: This type of installation is less common - only done when access door cannot be used.
1. Open wiring compartment by removing screws at each end and lifting cover from housing body. See Figure 8.
2. Punch out whichever knockout is best suited for connection to 120V supply wires. Knockouts are located along back and
top of housing. See Figure 9.
3. Install cable connnector and connect fixture wires following National Electric Code and/or local building code requirements.
Use minimum 18AWG solid copper wires. AC supply should be 120V protected by circuit breaker or fuse.
4. Attach line voltage AC supply wires to fixture lead wires: Black to Black/Hot, White to White/Neutral and Yellow/Green
(Ground) to Green or bare wire inside the fixture. Secure each connection using push-in wire connectors provided on the
fixture lead wire. If your system has no ground wire, consult a qualified electrician before proceeding with the installation.
Note: Electric shock, overheating, low or no light output and shortened fixture life can result if proper grounding is not
done.
5. Replace the wiring compartment cover, securing with the existing retaining screws. Note: Be sure that the wires are not
pinched or damaged by any part of the housing or the cover.
Model No.
Number of LEDs
Input Watts
ALC-8
7
2.8W
ALC-12
10
4.0W
ALC-18
15
6.0W
ALC-24
20
8.0W
ALC-32
27
10.8W
End
connector
cover
Denver, CO 80231 • American Lighting, Inc.
2013