3. I
nstall 3/4” cable connnector to this open knockout and connect
fixture wires following National Electric Code and/or local building
code requirements. Use minimum 18AWG solid copper wires. AC
supply should be protected by circuit breaker or fuse.
4.
Attach line voltage AC supply wires to fixture lead wires: Black to
Black/Hot, White to White/Neutral and Yellow/Green (Ground) to
Green or bare wire inside the fixture. Secure each connection using
UL Listed wire connectors. If your system has no ground wire, consult
a qualified electrician before proceeding with the installation. Note:
Electric shock, overheating, low or no light output and shortened
fixture life can result if proper grounding is not done. See Figure 3.
5.
Connect support cable kit to both sides of junction box housing
using slots in junction box side straps. See Figure 4.
6. Tie off cable kit to a plenum rated support of the building.
Alternatively, run appropriately sized lengths of empty conduit
through side straps in lieu of tying off.
7. Pull spring brackets upward (see Figure 6), then place the Downlight
into the ceiling (see Figure 7). Spring brackets will hold Downlight
securely in place.
Figure 3
Figure 4
Ceiling
Ceiling
Cable Kit
Tie off to
plenum rated
building
support
Cable
kit
RV1411 Page 2 of 2
Side strap
with slot
Figure 5
Figure 6
Figure 7
5- YEAR LIMITED PRODUCT WARRANTY
This product is warranted to be free from defects in material and
workmanship for a period of five years from the date of purchase.
Products that prove to be defective during this period will be
either repaired (i.e. replacement of defective electronics, defective
parts of the fixture housing, lens, wiring, switching or lamp
sockets; excluding the lamp) or replaced, at the discretion of
American Lighting, Inc. Claims for defective products must be
submitted to the retail location from which the product was
purchased within the warranty period. Upon submission of proper
return claim documentation and product to American Lighting,
Inc by the retailer, American Lighting, Inc reserves the right to
inspect the product for misuse or abuse. Claims for indirect or
consequential damages or for product that, in American Lighting
Inc's opinion has been misused will be denied. This is a warranty of
product reliability only and not a warranty of merchantability or
fitness for a particular purpose. American Lighting, Inc shall have
no liability whatsoever in any event for payment of incidental or
consequential damages, including, without limitations, installation
costs and damages for personal injury and property. These
products may represent a possible shock or fire hazard if
improperly installed or altered in any way. This warranty applies
only to product that has been properly installed in accordance
with instruction sheet and current local codes and/or the National
Electrical Code. Warranty does not apply to any product that has
been improperly installed or in situations where components have
been altered in any way.
For questions / comments, technical assistance or repair parts –