Memory recall, Global functions – Allen&Heath DP 1000 USER GUIDE User Manual
Page 53
M
EMORY
R
ECALL
MIDI control is now extended to the
VENUE memory recalls as well as SONG.
These use the same program change messages as before but different banks.
Refer also to the
icon User Guide which details the original MIDI functions
including
MUTE note on/off messages and system exclusive data archive.
SONG RECALL
Program change in Bank 1
0xBm, 0x00, 0x00, 0xCm, pp
Where
m is
MIDI channel number
pp is
0x00 =
SONG 1
0x7E =
SONG 127
0x7F =
PAUSE
VENUE RECALL
Program change in Bank 2
0xBm, 0x00, 0x01, 0xCm, pp
Where
m is
MIDI channel number
pp is
0x00 =
VENUE 1
0x12 =
VENUE 19
G
LOBAL
F
UNCTIONS
The following global functions are controlled using MIDI system exclusive
messages.
Where
MV is major version number 0… 127
Mv is minor version number 0… 127
m is
MIDI channel number
AMP MODE
Changes mix source to amplifier channels A and B:
0xF0,0x00,0x00,0x1A,0x50,0x07,MV,Mv,0x0m,0x03,Mode,0xF7
Where
Mode is
0x00 for
L R
0x01 for
FB M
0x02 for
Aux FB
AUX PRE/POST Switches all channel aux sends either pre or post fader:
0xF0,0x00,0x00,0x1A,0x50,0x07,MV,Mv,0x0m, 0x05, Pre/Post,0xF7
Where
Pre is 0x00
Post is 0x7F
TRIM ON/OFF Enables or disables the channel level trim parameter:
0xF0,0x00,0x00,0x1A,0x50,0x07,MV,Mv,0x0m, 0x04, Off/On,0xF7
Where
Off is 0x00
On is 0x7F
icon
SERIES