5 use of the capacity chart, Capacity indicator locations, 5 use of the capacity chart -4 – JLG G12-55A AccuPlace Operator Manual User Manual
Page 72: Capacity indicator locations -4
Section 5 - Attachments
5-4
3128447
5.5
USE OF THE CAPACITY CHART
To properly use the capacity chart (see page 5-6), the operator must first determine
and/or have the following:
1. An approved attachment. See “Approved Attachments” on page 5-1.
2. The proper Capacity Chart(s).
3. Weight of the load being lifted.
4. Load placement information:
a. HEIGHT where the load is to be placed.
b. DISTANCE from the front tires of the telehandler to where the load is to be
placed.
5. On the capacity chart, find the line for the height and follow it over to the
distance.
6. The number in the load zone where the two cross is the maximum capacity for
this lift. If the two cross at a division between zones, the smaller number must
be used.
The number in the load zone must be equal to or greater than the weight of the load
to be lifted. Determine the limits of the load zone on the capacity chart and keep
within these limits.
Capacity Indicator Locations
OY1510
-10 10
20 30
40 50
60 7
080
DO NOT GO NEAR LEAKS
C
10814B
* High pressure oil easily punctures skin causing serious injury, gangrene or death.
* If injured, seek emergency medical help. Immediate surgery is required to remove oil.
* Do not use finger or skin to check for leaks.
* Lower load or relieve hydraulic pressure before loosening fittings.
BOOM
EXTENSION
INDICATOR
BOOM ANGLE
INDICATOR
ATTACHMENT
IDENTIFICATION
PLATE
FORK
WEIGHT
STAMP