2 thermal limit (soa), 4 battery supply, 2 thermal limit (soa) -22 4-4 battery supply -22 – JLG 1230ES Operator Manual User Manual
Page 85

SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
3121221
– JLG Lift –
6-21
4-2 Thermal Limit (SOA)
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
421
POWER MODULE TOO HOT - PLEASE
WAIT
The power module has reached thermal cut-
out.
• Power down and allow to cool.
• Do not operate in ambients over 140° F (60° C).
Refer problem to a qualified JLG mechanic.
422
DRIVING AT CUTBACK - POWER MOD-
ULE CURRENT LIMIT
The drive portion of the power module has
reached thermal limit.
Refer problem to a qualified JLG mechanic.
423
LIFT UP AT CUTBACK - POWER MODULE
CURRENT LIMIT
The lift up portion of the power module has
reached thermal limit.
Refer problem to a qualified JLG mechanic.
4-4 Battery Supply
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
441
BATTERY VOLTAGE TOO LOW - SYSTEM
SHUTDOWN
A problem has been detected with the bat-
teries or power module.
• Recharge batteries or check for damaged batteries.
• Check battery charger function.
Refer problem to a qualified JLG mechanic.
442
BATTERY VOLTAGE TOO HIGH - SYSTEM
SHUTDOWN
A problem has been detected with the bat-
teries or power module.
• May be due to improper battery charging or incorrect voltage batteries
being used.
Refer problem to a qualified JLG mechanic.
443
LSS BATTERY VOLTAGE TOO HIGH
A problem has been detected with the load
sense system.
• May be due to improper battery charging or incorrect voltage batteries
being used.
Refer problem to a qualified JLG mechanic.